Thrombus management

  • The OptionELITE inferior vena cava filter protects against recurrent pulmonary embolism (PE). It can be retrieved or remain implanted depending on whether the patient needs short-term or long-term PE protection. With over six years of positive, consistent and proven clinical performance, the OptionELITE filter has a unique anchoring system that makes retrievals easier. The OptionELITE is cleared for delivery using a standard or over-the-wire technique via jugular, femoral, antecubital, or popliteal access.

    Unique open apex design for easy snare capture and retention at retrieval. Open apex design for snare retention at retrieval. Single piece nitinol construction for enhanced structural integrity. Electropolished for increased fracture resistance. Innovative anchor design for stability and retrievability in cava diameters up to 30mm. Curved anchors for cranial migration prevention. Anchor grips for caudal migration prevention. Leg extensions for perforation prevention.

    Learn More →
  • The only wall-contacting rotational thrombectomy system indicated for mechanical declotting and infusion of thrombolytics in the peripheral vasculature.

    Indicated for use in both the peripheral vasculature and in AV dialysis fistulae/grafts. Available in 65cm length for upper extremity or short-reach needs. Available in 135cm length for popliteal/femoral access or other long-reach needs.

    Learn More →
  • The only wall-contacting rotational thrombectomy system indicated for mechanical declotting and infusion of thrombolytics in the peripheral vasculature.

    Indicated for use in both the peripheral vasculature and in AV dialysis fistulae/grafts. Available in 65cm length for upper extremity or short-reach needs. Available in 135cm length for popliteal/femoral access or other long-reach needs.

     

    Learn More →

CLEANER XT™ ROTATIONAL THROMBECTOMY SYSTEM

Submitted by Dev_medi on

The only wall-contacting rotational thrombectomy system indicated for mechanical declotting and infusion of thrombolytics in the peripheral vasculature.

Indicated for use in both the peripheral vasculature and in AV dialysis fistulae/grafts. Available in 65cm length for upper extremity or short-reach needs. Available in 135cm length for popliteal/femoral access or other long-reach needs.

CLEANER15™ ROTATIONAL THROMBECTOMY SYSTEM

Submitted by Dev_medi on

The only wall-contacting rotational thrombectomy system indicated for mechanical declotting and infusion of thrombolytics in the peripheral vasculature.

Indicated for use in both the peripheral vasculature and in AV dialysis fistulae/grafts. Available in 65cm length for upper extremity or short-reach needs. Available in 135cm length for popliteal/femoral access or other long-reach needs.